1. This test serves to
ensure that no air
is present in this
separate hydraulic
circuit.
2. [Y] =Con. [N] =Return
3) Follow onscreen instructions to finish the first phase of operation:
- Pressure reservoir: check pretension pressure.
- Actuation takes about 30s.
4) Press Y button or gently actuate and then release the brake pedal
to continue.
If you do not wish to continue, press N button to exit and a
User Aborted!” message comes up.
You can exit the air inspection service at any phase of the
operation with N button.
5) Wait a few seconds while the device is communicating with the
vehicle. And follow onscreen instructions to finish the second
phase of operation:
- The brake system pressure reservoir is OK.
- Check fill status of rear wheel brake circuits.
6) Press Y button or gently actuate and then release the brake pedal
as instructed to continue.
7) Wait a few seconds while the device is communicating with the
vehicle. And follow onscreen instructions to finish the third phase
of operation:
- Brake system fill status is OK.
- Check fill status of pedal travel simulator.
8) Press Y button or gently actuate and then release the brake pedal
as instructed to continue.
9) Use UP/DOWN button to view onscreen prompts
........ Inspect Brake Air .... .
1/2
1. Increase brake
pressure slowly and
evenly.
2. Brake pressure must
not rise beyond the
specified range!