Symptom Possible Causes Corrective Action
• Claw or shovel erratic. • External leakage.
• Binding sticking or components.
• Contact Sealey dealer for service.
• Clean and lubricate all moving parts.
• System is pressurised but the bead breaker
is not responding.
• Loose or faulty hydraulic connections/couplers.
• Oil level in pump is low.
• Pump not operating.
• Depressurise Tighten/replace
connections/couplers.
• Depressurise and ll the pump.
• Consult pump instruction manual.
• Claw will not close or shovel will not fully
extend or withdraw.
• Oil in pump is low.
• Sticking rams or binding components.
• Depressurise and ll the pump.
• Contact Sealey dealer for service.
• Bead breaker will not maintain pressure. • Pump malfunctioning.
• Seals leaking.
• Consult pump instruction manual.
• Contact Sealey dealer for service.
• Oil leaking. • Worn seals. • Contact Sealey dealer for service.
• Bead breaker will not open and/or shovel
stuck or slower than normal.
• Faulty coupler.
• Pump reservoir over lled.
• Internal damage.
• Linkage binding.
• Depressurise Tighten/replace
connections/couplers.
• Depressurise and drain uid to correct
level.
• Contact Sealey dealer for service.
• Clean and lubricate all moving parts.